Home About Us News Product Tech Support Contact Us Chinese
   
Home - Product Center - Electronic Level


ProductName: LE-60
Content:

Product Features
1. Through silicon micro-machined sensor measures changes in biaxial angle to the horizontal surface as the reference plane.
2. Optional RS232 interface and 485 interface.
3. Calibrate zero plane through serial instructions.
4. Waterproof house structure , anti-interference capability.
 
Product Description
LE-60 is biaxial angle sensor, by measuring the static acceleration of gravity change, change into angle changes. Measurement sensor output is relative to the pitch and roll angle, built-in automatic temperature compensation .Sensor response rate from 4Hz to 12.8Hz that is adjustable. Built-in impact suppression mode, distinguish impact vibration and inclination changes.
 
 Specifications
1.       Conventional models of key indicators (power = +12 V)
Range
Biaxial ¡À15 ¡À30 ¡À45 ¡À60         deg
Resolution
¡À0.02                                         deg
Accuracy
<¡À0.1                                         deg
Non linearity
¡À0.1%
Repeatability
¡À0.05                                         deg
Angle drift
0.01¡ã/¡æ
Response rate
4Hz¡«12.8Hz
2.       Other Parameters
Item
   Min
 Normal
   Max
 Units
Supply Voltage
5.5
9
15
V
Current
50
55
60
MA
Serial data format
9600,n,8,1
Operating Temp
-40
 
+80
¡æ
3. Limits
Item
Min
Max
Units
Supply Voltage
5
18
       V
Operating Temp
-55
+100
¡æ
 
 Digital Output Format
1 Transmission Commands Format
Byte position
Meaning
Date
1,2
Header
0xAA ,0xAA
3
Data Length
0x04
4
Sensor addresses
0Xxx
5
Command
0x01
6
Checking byte
The above data XOR
2 Receive output format
Byte position
Meaning
Data Types
       Comment
1,2
Header
 
0xAA,0xAA
3
Frame size
Byte
Date length outside the header
4
Addresses
Byte
0Xxx
5
Order returns
Byte
 
6,7
Reservations
 
 
8,9
Reservations
 
 
10,11
Angle of X
Integer
Angle= Integer/100(deg)
12,13
Angle of Y
Integer
Angle= Integer/100(deg)
14
Reservations
Integer
Internal temp(error¡À3deg)
15
Checking byte
Byte
The above data XOR
 
Command Table
Commands
Meaning
Comment
0x01-0x05
Set the output speed
0x01-20Hz-------0x05-5Hz
0xa0
Single output
 
0xa1
Continuous output
Data output as the response speed
0xb6
 Calibration 1
Place the sensor at arbitrary position
0xb7
Calibration 2
Reverse 180 degrees to place the sensor
0xb8
Parameters preservation
 
0xd0
X  zero-Angle setting
 
0xd1
Y  zero-Angle setting
 
0xd2
Remove setting
Remove the zero-angle by ¡®0xd0¡¯ ¡®0xd1¡¯
0xf1
Hex-output
 
0xf0
 Ascii-output
 
 
Pin Diagram
Pin numbers
Name
Comment
1
GND
Ground
2
+12V
Positive electrode
3
NC
 
4
NC
 
5
RXI
 
6
TX0
 
7
NC
Linking Ban
 
house size
   1 Size: 90¡Á60¡Á30 mm
   2 Dimension show:
 
 
[ Close This Window ]
 

 
 
Copyright © 2006- 2007 SPACEFLIGHT THE GREAT WALL TECHNOLOGY. All Rights Reserved
Address: Chang Ying East Road, Xi'an¡¡Post Code: 710032 Tel:+86 29 82501390  Fax: +86 29 82501710